178004-01
Coils and Transformers
TRANSFORMER,POWER
178004-01
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Width
2.500 inches nominal
-
Body Length
3.062 inches nominal
-
Winding Shielding Method
internal shield grounded to inclosure and core single component
-
Winding Operating Voltage
35.00 ac volts nominal single component 2nd secondary
-
Overall Length
3.062 inches nominal
-
Nominal Thread Size
0.164 inches single group
-
Winding Operating Voltage
7.00 ac volts nominal single component 1st secondary
-
Winding Tap Location (Non-Core)
err-070
-
Mounting Method
threaded stud single group
-
Thread Quantity Per Inch
32 single group
-
Winding Function And Quantity
1 primary single component and 2 secondary single component
-
Inclosure Type
partially inclosed, half shell
-
Terminal Type And Quantity
8 tab, solder lug
-
Winding Operating Current
10.0 milliamperes ac maximum single component 1st secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.000 inches nominal single mounting facility single center group
-
Frequency Rating
50.0 hertz nominal single component and 60.0 hertz nominal single component
-
Maximum Operating Temp
105.0 deg celsius
-
Reliability Indicator
not established
-
Overall Width
2.500 inches nominal
-
Body Height
2.500 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.500 inches nominal single mounting facility single center group
-
Winding Operating Current
1.5 amperes ac maximum single component 2nd secondary
-
Input-Output Phase Relationship
single phase to single phase single component
-
Thread Series Designator
unc single group
-
Overall Height
2.500 inches maximum
-
Mounting Facility Quantity
4 single group
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary and 105.00 ac volts nominal single component single primary and 125.00 ac volts nominal single component single primary