10333613

Circuit Breakers

CIRCUIT BREAKER

10333613

5925-00-789-3698

5925 - Circuit Breakers

U S Army Armament Research &

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    2a single pole type

  • Bushing Length

    0.360 inches minimum and 0.380 inches maximum

  • Case Material

    metal

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Iii Storage Type

    general purpose warehouse

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac and 500.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.375 inches

  • Thread Series Designator

    unef

  • Thread Pitch Diameters

    0.3503 to 0.3537 inches

  • Body Length

    1.448 inches minimum and 1.510 inches maximum

  • Body Width

    0.567 inches minimum and 0.629 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.870 inches minimum and 0.880 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.524 inches minimum and 1.586 inches maximum

  • Pole Quantity

    1

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac and 10.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac and 50.0 dc single location

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.650 minimum at 200 pct and 1.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    dustproof

  • Frequency In Hertz

    60.0 single location

  • Terminal Type And Quantity

    2 wire hook

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...