271-11031P2
Circuit Breakers
CIRCUIT BREAKER
271-11031P2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Bushing Length
0.390 inches maximum
-
Body Length
1.562 inches maximum
-
Case Material
metal
-
Center To Center Distance Between Terminals Parallel To Length
1.885 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.656 inches maximum
-
Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
1.828 inches maximum
-
Pole Quantity
2
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Position Designation
at pole two
-
Internal Trip Release Configuration
series trip
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Frequency In Hertz
60.0
-
Unpackaged Unit Weight
4.500 ounces
-
Precious Material And Location
terminal and contact surface silver
-
Precious Material
silver
-
Thread Series Designator
unef
-
Body Width
1.937 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac
-
Circuit Protection Type
overcurrent
-
Trip Release Method
magnetic-hydraulic
-
Trip Release Characteristic
time delay
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Reset Method
manual
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Nominal Thread Size
0.375 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.850 minimum at 200 pct and 4.500 maximum at 200 pct
-
Terminal Type And Quantity
6 wire hook