10049996-2
Circuit Breakers
CIRCUIT BREAKER
10049996-2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Terminal Type And Quantity
2 wire hook
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Unpackaged Unit Weight
2.100 ounces
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Center To Center Distance Between Terminals Parallel To Length
0.687 inches nominal
-
Mounting Facility Type And Quantity
thd bushing
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Pole Quantity
1
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Trip Release Method
thermal-magnetic single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct single location and 0.800 maximum at 200 pct single location
-
Trip Release Characteristic
time delay single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Maximum Continuous Load Current Rating Per Pole
3.0 amperes dc single location
-
Ultimate Trip Time Per Pole In Seconds
1.000 minimum single location and 4.000 maximum single location
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
-
Body Style
single pole type
-
Body Width
0.625 inches maximum
-
Thread Series Designator
unef
-
Body Length
1.750 inches maximum
-
Mounting Surface To Terminal End Distance
1.635 inches nominal
-
Inclosure Protection Type For Which Designed
shockproof and vibrationproof and hermetically sealed
-
Bushing Length
0.315 inches nominal