9T33Y4022
Coils and Transformers
TRANSFORMER,POWER
9T33Y4022
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
2.875 inches nominal
-
Body Width
2.156 inches nominal
-
Body Height
2.750 inches nominal
-
Inclosure Type
open
-
Winding Function And Quantity
1 primary single component and 4 secondary
-
Winding Tap Location
center tap single component 1st secondary
-
Winding Tap Location
center tap single component single primary
-
Winding Operating Current
16.0 milliamperes ac maximum single component 2nd secondary
-
Winding Operating Current
175.0 milliamperes ac maximum single component 1st secondary
-
Winding Operating Current
2.0 amperes ac maximum single component 3rd secondary
-
Winding Operating Voltage
1.12 ac kilovolts nominal single component 2nd secondary
-
Winding Operating Voltage
5.00 ac volts nominal single component 3rd secondary
-
Distance Between Mounting Facility Centers
1.625 inches nominal single mounting facility single center group
-
Mounting Facility Quantity
2 single group
-
Mounting Method
flange single group and slot
-
Winding Operating Current
2.0 amperes ac maximum single component 4th secondary
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Winding Operating Voltage
5.00 ac volts nominal single component 4th secondary
-
Winding Operating Voltage
800.00 ac volts nominal single component 1st secondary
-
Terminal Type And Quantity
12 tab, solder lug
-
Reliability Indicator
not established
-
Mounting Slot Width
0.156 inches nominal single group
-
Frequency Rating
380.0 hertz minimum single component and 1.76 kilohertz maximum
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Shielding Method
internal shield grounded to core single component