JL3M150

Circuit Breakers

CIRCUIT BREAKER

JL3M150

5925-00-801-7099

5925 - Circuit Breakers

Siemens Energy And Automation Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Features Provided

    adjustable trip release

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +750.0/+1600.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    480.000 nominal at 200 pct all locations

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    3.000 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Body Width

    9.000 inches nominal

  • Body Height

    4.062 inches nominal

  • Actuator Position Designation

    at pole two

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Body Style

    multipole-single actuator type

  • Boss Height

    0.250 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Thread Quantity Per Inch

    20

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    3.000 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations

  • Body Length

    11.000 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    150.0 amperes ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    8.000 inches nominal

  • Mounting Facility Type And Quantity

    4 threaded stud

  • Nominal Thread Size

    0.250 inches

  • Ultimate Trip Time Per Pole In Seconds

    7200.000 nominal all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    9.750 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...