MIL-C-7079

Circuit Breakers

CIRCUIT BREAKER

MIL-C-7079

5925-00-802-1243

5925 - Circuit Breakers

Military Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Inclosure Protection Type For Which Designed

    explosion resistant and corrosion resistant

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc single location

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct all locations and 50.000 maximum at 200 pct all locations

  • Reset Method

    manual

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • ~1

    data on certain environmental and performance

  • Test Data Document

    81349-mil-c-7079 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Thread Series Designator

    unc

  • Bushing Length

    0.250 inches nominal

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    30.0 dc single location

  • Body Width

    0.750 inches maximum

  • Specification/Standard Data

    96906-ms24506 government standard

  • Terminal Type And Quantity

    2 tab w/screw

  • Ultimate Trip Time Per Pole In Seconds

    60.000 maximum single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Body Style

    single pole type

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3000.0 dc single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Body Length

    2.189 inches maximum

  • Pole Quantity

    1

  • Main Contact Tripping Mechanism Type

    nontrip free

  • Manual Actuator Type And Quantity

    1 push-pull

  • Trip Release Method

    thermal single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.188 inches nominal

  • Circuit Protection Type

    overcurrent single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...