24-8942

Circuit Breakers

CIRCUIT BREAKER

24-8942

5925-00-803-1928

5925 - Circuit Breakers

York International Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.300 minimum at 200 pct single location and 50.000 maximum at 200 pct single location

  • Boss Height

    0.125 inches nominal

  • Body Height

    2.656 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Body Style

    single pole type

  • Body Width

    1.468 inches nominal

  • Trip Release Method

    magnetic-hydraulic single location

  • Frequency In Hertz

    60.0 single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.312 inches nominal

  • Terminal Type And Quantity

    2 compression

  • Case Material

    plastic

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes ac single location

  • Trip Release Characteristic

    time delay single location

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Center To Center Distance Between Terminals Parallel To Length

    2.750 inches nominal

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Body Length

    3.218 inches nominal

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac single location

  • Thread Series Designator

    unc

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...