Circuit Breakers

CIRCUIT BREAKER

64-184-2-MG4

5925-00-803-4539

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Boss Height

    0.208 inches minimum and 0.228 inches maximum

  • Mounting Facility Type And Quantity

    12 threaded hole and 12 unthreaded hole

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Operating Voltage Type And Rating Per Pole In Volts

    416.0 ac all locations

  • Thread Series Designator

    unc

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Fragility Factor

    moderately rugged

  • Case Material

    plastic

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.320 minimum at 200 pct all locations and 1.000 maximum at 200 pct all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Body Length

    5.240 inches minimum and 5.260 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.990 inches minimum and 1.010 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Length

    4.349 inches minimum and 4.369 inches maximum

  • Nominal Thread Size

    0.164 inches

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes ac all locations

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Width

    4.490 inches minimum and 4.510 inches maximum

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Terminal Type And Quantity

    6 compression

  • Center To Center Distance Between Terminals Parallel To Width

    0.990 inches minimum and 1.010 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic-hydraulic all locations

  • Thread Quantity Per Inch

    32

  • Body Height

    2.677 inches minimum and 2.697 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.052 inches minimum and 3.072 inches maximum

  • Storage Type

    general purpose warehouse

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...