Technical Characteristics
-
Winding Operating Voltage
296.00 ac volts nominal single component 2nd secondary
-
Winding Operating Voltage
210.00 ac volts nominal single component single primary
-
Adjustment Method And Quantity
1 adjustable control single component
-
Winding Operating Current
3.0 milliamperes ac maximum single component 2nd secondary
-
Winding Operating Current
16.0 milliamperes ac maximum single component 3rd secondary
-
Winding Operating Current
110.0 milliamperes ac maximum single component 1st secondary
-
Inclosure Type
open
-
Maximum Operating Temp
115.0 deg celsius
-
Body Height
3.000 inches nominal
-
Body Length
4.000 inches nominal
-
Winding Shielding Method
internal shield grounded to core single component
-
Transformer Winding Connection Type
open delta-open delta
-
Input-Output Phase Relationship
single phase to three phase single component
-
Mounting Slot Width
0.094 inches nominal single group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.750 inches nominal single mounting facility single center group
-
Terminal Type And Quantity
12 tab, solder lug
-
Special Features
transformer shall operate at an altitude of 15000 feet
-
Winding Operating Voltage
315.00 ac volts nominal single component 3rd secondary
-
Winding Operating Voltage
229.00 ac volts nominal single component 1st secondary
-
Winding Function And Quantity
1 primary and 3 secondary single component
-
Mounting Method
slot single group
-
Mounting Facility Quantity
4 single group
-
Body Width
2.375 inches nominal
-
Adjustment Device Drive Type
shaft single component
-
Frequency Rating
380.0 hertz minimum and 420.0 hertz maximum single component
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.625 inches nominal single mounting facility single center group
-
Reliability Indicator