6755-1-5

Circuit Breakers

CIRCUIT BREAKER

6755-1-5

5925-00-809-1798

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Actuator Function

    reset

  • Bushing Length

    0.250 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    0.812 inches nominal

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac single location and 500.0 dc single location

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Body Width

    0.750 inches nominal

  • Manual Actuator Type And Quantity

    1 push button

  • Terminal Type And Quantity

    2 screw

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Nominal Thread Size

    0.468 inches

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 30.0 dc single location

  • Body Length

    1.094 inches nominal

  • Body Style

    single pole type

  • Inclosure Protection Type For Which Designed

    explosion resistant and fungus proof and corrosion resistant

  • Mounting Surface To Terminal End Distance

    0.813 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Frequency In Hertz

    60.0 single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    0.782 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 120.000 maximum at 200 pct single location

  • Thread Series Designator

    uns

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...