10373685

Circuit Breakers

CIRCUIT BREAKER

10373685

5925-00-809-1800

5925 - Circuit Breakers

Army United States Department Of The

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Thread Series Designator

    uns

  • Nominal Thread Size

    0.469 inches

  • Ultimate Trip Time Per Pole In Seconds

    3600.000 maximum single location

  • Mounting Surface To Terminal End Distance

    1.312 inches maximum

  • Terminal Type And Quantity

    2 tab w/screw

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac single location and 20.0 amperes dc single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    25.000 minimum at 200 pct single location and 100.000 maximum at 200 pct single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac single location and 4000.0 dc single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Body Length

    2.189 inches maximum

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Release Method

    thermal single location

  • Inclosure Protection Type For Which Designed

    explosion resistant and corrosion resistant and fungus proof

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Manual Actuator Type And Quantity

    1 push button

  • Actuator Function

    trip-reset

  • Body Width

    0.750 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Bushing Length

    0.250 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...