4076
Coils and Transformers
TRANSFORMER,POWER
4076
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.500 inches nominal single mounting facility single center group
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.000 inches nominal single mounting facility single center group
-
Body Length
3.000 inches nominal
-
Body Height
3.500 inches nominal
-
Inclosure Type
partially inclosed, half shell
-
Thread Quantity Per Inch
32 single group
-
Mounting Method
threaded stud single group
-
Nominal Thread Size
0.164 inches single group
-
Frequency Rating
50.0 hertz minimum single component and 1.0 kilohertz maximum single component
-
Winding Function And Quantity
2 primary single component and 2 secondary single component
-
Winding Operating Current
2.0 amperes dc maximum single component 1st secondary
-
Body Width
2.500 inches nominal
-
Mounting Facility Quantity
4 single group
-
Winding Operating Voltage
600.00 ac volts nominal single component 2nd secondary
-
Winding Operating Current
30.0 milliamperes dc maximum single component 2nd secondary
-
Winding Operating Voltage
12.50 ac volts nominal single component 1st secondary
-
Terminal Type And Quantity
10 tab, solder lug
-
Special Features
case metal material
-
Winding Operating Voltage
115.00 ac volts nominal single component all primary
-
Thread Series Designator
unc single group
-
Winding Shielding Method
internal shield grounded to inclosure single component
-
Input-Output Phase Relationship
single phase to single phase single component