AM12HKMG6-10-50VDC4
Circuit Breakers
CIRCUIT BREAKER
AM12HKMG6-10-50VDC4
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Inclosure Protection Type For Which Designed
dusttight and sand resistant and humidity resistant and shock resistant and salt spray proof and vibration resistant and moisture resistant and fungus resistant and explosion resistant
-
Fragility Factor
moderately rugged
-
Trip Release Method
magnetic single location
-
Boss Height
0.132 inches minimum and 0.135 inches maximum
-
Switch Terminal Type
tab, solder lug
-
Special Handling Feature
magnetic
-
Thread Series Designator
unc
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes dc single location
-
Body Length
2.530 inches maximum
-
Mounting Facility Type And Quantity
2 threaded hole
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.070 inches minimum and 2.090 inches maximum
-
Thread Quantity Per Inch
32
-
Mounting Surface To Terminal End Distance
2.495 inches maximum
-
Pole Quantity
1
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Switch Current Rating And Type In Amps
2.5 ac and 1.0 dc
-
Switch Contact Arrangement
single pole, double throw
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc single location
-
Circuit Protection Type
overcurrent single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.180 minimum at 200 pct single location and 0.500 maximum at 200 pct single location
-
Terminal Type And Quantity
2 threaded stud
-
Case Material
plastic
-
Switch Location And Position Designation
internal at pole one
-
Body Width
0.757 inches minimum and 0.760 inches maximum
-
Auxiliary Switch Function And Quantity
1 alarm
-
Unpackaged Unit Weight
4.250 pounds
-
Body Style
single pole type
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
-
Arc Quenching Method
magnetic blowout
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Trip Release Characteristic
time delay single location
-
Nominal Thread Size
0.138 inches
-
Internal Trip Release Configuration
series trip single location
-
Manual Actuator Type And Quantity
1 toggle