MVA620-1
Switches
SWITCH,PRESSURE
MVA620-1
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Action Stimulus
decrease
-
Width Across Flats
0.687 inches nominal
-
Nominal Thread Size
0.4375 inches single pressure connection
-
Pressure Switch Type
differential
-
Overall Diameter
1.500 inches maximum
-
Thread Series Designator
unef single pressure connection
-
Contact Voltage Rating In Volts
28.0 dc at altitude single voltage
-
Overall Length
3.800 inches maximum
-
Pressure Connector Type
gasket seal, threaded internal single connection
-
Nonpile-Up Contact Arrangement
1 pole, double throw, both positions maintained
-
Thread Class
3b single pressure connection
-
Operating Temp Rating
-65.0 deg fahrenheit minimum and 275.0 deg fahrenheit maximum
-
Body Length
1.700 inches maximum
-
Contact Stimulus Rating
100.00 differential point nominal pounds per square inch gage
-
Mounting Method
clamp
-
Inside Diameter
0.250 inches nominal single connection
-
Sensing Element Burst Pressure
7500.00 pounds per square inch
-
Media For Which Designed
liquid
-
Terminal Type
connector, receptacle
-
Err Default
err default
-
Style Designator
cylindrical
-
Contact Load Current Rating
3.0 amperes inductive load single voltage
-
Thread Quantity Per Inch
20 single pressure connection
-
Contact Adjustability
deactuation point not adjustable and actuation point not adjustable