Technical Characteristics
-
Bushing Length
0.250 inches nominal
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.300 minimum at 200 pct single location and 0.900 maximum at 200 pct single location
-
Thread Series Designator
unc
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.812 inches nominal
-
~1
data on certain environmental and performance
-
Pole Quantity
1
-
Body Length
2.189 inches maximum
-
Internal Trip Release Configuration
series trip single location
-
Test Data Document
81349-mil-c-7079 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Mounting Surface To Terminal End Distance
2.000 inches maximum
-
Circuit Protection Type
overcurrent single location
-
Center To Center Distance Between Terminals Parallel To Length
1.188 inches nominal
-
Trip Release Method
thermal single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Main Contact Tripping Mechanism Type
nontrip free
-
Nominal Thread Size
0.138 inches
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Inclosure Protection Type For Which Designed
explosion proof and corrosion resistant
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3000.0 dc single location
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Terminal Type And Quantity
2 tab w/screw
-
Specification/Standard Data
96906-ms24506 government standard
-
Body Width
0.750 inches maximum
-
Ultimate Trip Time Per Pole In Seconds
3600.000 maximum single location
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc single location
-
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc single location
-
Case Material
plastic