Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.110 minimum at 200 pct single location and 0.600 maximum at 200 pct single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Unpackaged Unit Weight

    4.250 ounces

  • Mounting Surface To Terminal End Distance

    2.625 inches maximum

  • Inclosure Protection Type For Which Designed

    fungus proof and shock resistant and humidity resistant and salt spray proof and vibration resistant

  • Boss Height

    0.109 inches minimum and 0.141 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.922 inches minimum and 1.953 inches maximum

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

  • Special Features

    weapons system critical item

  • Nominal Thread Size

    0.138 inches

  • Body Width

    0.734 inches minimum and 0.766 inches maximum

  • Actuator Position Designation

    at pole one

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Criticality Code Justification

    feat

  • Actuator Function

    trip-reset

  • Body Length

    2.484 inches minimum and 2.516 inches maximum

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.047 inches minimum and 1.078 inches maximum

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Precious Material And Location

    contacts and other current carrying surfaces silver

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Thread Series Designator

    unc

  • Maximum Continuous Load Current Rating Per Pole

    4.4 amperes ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...