7724138
Coils and Transformers
TRANSFORMER,POWER
7724138
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Voltage
21.20 ac volts nominal single component single secondary or 19.10 ac volts nominal single component single secondary or 23.30 ac volts nominal single component single secondary
-
Mounting Facility Quantity
4 single group
-
Body Height
4.250 inches maximum
-
Maximum Operating Temp
65.0 deg celsius
-
Supplementary Features (Non-Core)
storage temp range minus 55 deg c to plus 85 deg c
-
Winding Shielding Method
internal shield grounded to inclosure and core single component
-
Unpackaged Unit Weight (Non-Core)
4.400 pounds
-
Winding Operating Current
816.0 milliamperes ac maximum single component single secondary
-
Nominal Thread Size
0.164 inches single group
-
Mounting Method
threaded stud single group
-
Thread Quantity Per Inch
32 single group
-
Body Width
2.620 inches maximum
-
Overall Height
4.650 inches maximum
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Input-Output Phase Relationship
three phase to three phase single component
-
Winding Operating Voltage
208.00 ac volts nominal single component single primary
-
Frequency Rating
47.0 hertz minimum single component and 63.0 hertz maximum single component
-
Test Data Document
03538-7724138 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Reliability Indicator
not established
-
Body Length
3.060 inches maximum
-
Terminal Type And Quantity
12 tab, solder lug
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.297 inches maximum single mounting facility single center group
-
Inclosure Type
hermetically sealed
-
Thread Series Designator
unc single group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.859 inches maximum single mounting facility single center group