613440-L
Relays and Solenoids
RELAY,ELECTROMAGNETIC
613440-L
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes ac resistive load and 10.0 amperes dc resistive load
-
Nominal Operating Current Rating And Type
300.0 milliamperes dc single winding
-
Mounting Facility Type And Quantity
4 unthreaded hole single mounting facility
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.625 inches nominal single mounting facility
-
Mounting Facility Pattern
rectangular single mounting facility
-
Environmental Protection
explosion proof
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Overall Width
3.120 inches nominal
-
Overall Length
3.120 inches nominal
-
Winding Quantity
1
-
Features Provided
polarized
-
Overall Height
2.870 inches nominal
-
Unthreaded Mounting Hole Diameter
0.196 inches nominal single mounting facility
-
Main Contact Maximum Voltage Rating In Volts
200.0 ac and 26.0 dc
-
Terminal Type And Quantity
8 pin all functions
-
Operating Voltage Rating And Type At Specified Temp
29.0 volts teardrop, two holes type 4f single winding
-
Coil Quantity
1
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.625 inches nominal single mounting facility
-
Duty Type
continuous