Technical Characteristics

  • Body Style

    15b multipole-single actuator type

  • Body Width

    3.344 inches nominal

  • Body Height

    3.375 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    2.625 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.125 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    0.500 inches nominal

  • Iii Fragility Factor

    moderately rugged

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Iii Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    24

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    instantaneous and time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Nominal Thread Size

    0.216 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct and 200.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    shockproof

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Terminal Type And Quantity

    6 quick disconnect, male

  • Body Length

    4.125 inches nominal

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.938 inches nominal

  • Boss Height

    0.125 inches nominal

  • Pole Quantity

    3

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations

  • Trip Release Method

    thermal all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Internal Trip Release Configuration

    series trip all locations

  • Frequency In Hertz

    60.0 all locations

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...