ETN1047

Circuit Breakers

CIRCUIT BREAKER

ETN1047

5925-00-817-7860

5925 - Circuit Breakers

Spd Electrical Systems Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Width

    1.125 inches nominal

  • Boss Height

    0.125 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Terminal Type And Quantity

    6 quick disconnect, male

  • Center To Center Distance Between Terminals Parallel To Length

    2.625 inches nominal

  • Internal Trip Release Configuration

    relay trip all locations

  • Body Height

    3.375 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.625 inches nominal

  • Body Length

    4.125 inches nominal

  • Frequency In Hertz

    400.00 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Reset Method

    manual

  • Body Width

    3.343 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.000 inches nominal

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Unthreaded Mounting Hole Diameter

    0.125 inches nominal

  • Actuator Position Designation

    at pole two

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Body Style

    multipole-single actuator type

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct all locations and 200.000 maximum at 200 pct all locations

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac all locations

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...