3363S6-3-250VAC60-2

Circuit Breakers

CIRCUIT BREAKER

3363S6-3-250VAC60-2

5925-00-819-3985

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    6 threaded stud

  • Case Material

    plastic

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.500 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Center To Center Distance Between Terminals Parallel To Length

    4.359 inches nominal

  • Mounting Surface To Terminal End Distance

    2.969 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.000 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Boss Height

    0.219 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Nominal Thread Size

    0.164 inches

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.000 inches nominal

  • Frequency In Hertz

    60.0 all locations

  • Body Width

    2.984 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Style

    multipole-single actuator type

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Actuator Position Designation

    at pole two

  • Trip Release Method

    magnetic all locations

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Body Length

    5.250 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.359 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Maximum Continuous Load Current Rating Per Pole

    6.3 amperes ac all locations

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Center To Center Distance Between Terminals Parallel To Width

    0.980 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Ultimate Trip Time Per Pole In Seconds

    22.500 minimum all locations and 125.000 maximum all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...