D7271-8-15

Circuit Breakers

CIRCUIT BREAKER

D7271-8-15

5925-00-821-2109

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performance

  • Fragility Factor

    moderately rugged

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac all locations and 3500.0 dc all locations

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    1.343 inches maximum

  • Unpackaged Unit Weight

    0.078 pounds

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches minimum and 0.937 inches maximum

  • Pole Quantity

    1

  • Case Material

    metal

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Inclosure Protection Type For Which Designed

    dusttight and sand resistant and vibration resistant and shockproof and corrosion resistant and explosion proof and moisture resistant

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location and 15.0 amperes dc single location

  • Bushing Length

    0.313 inches minimum and 0.375 inches maximum

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 70.000 maximum at 200 pct single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Width

    0.750 inches maximum

  • Specification/Standard Data

    96906-ms24510 government standard

  • Body Length

    1.375 inches maximum

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...