1500-016-3

Circuit Breakers

CIRCUIT BREAKER

1500-016-3

5925-00-821-5463

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.859 inches maximum

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac single location and 3.0 amperes dc single location

  • Inclosure Protection Type For Which Designed

    vibrationproof

  • Unpackaged Unit Weight

    0.100 pounds

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.655 inches minimum and 0.685 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 28.0 dc single location

  • Body Width

    0.673 inches minimum and 0.703 inches maximum

  • Special Features

    includes protection barriers at terminals

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    1.200 inches minimum and 1.230 inches maximum

  • Frequency In Hertz

    400.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac single location and 6000.0 dc single location

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Bushing Length

    0.250 inches maximum

  • Trip Release Characteristic

    instantaneous single location

  • Nominal Thread Size

    0.469 inches

  • Thread Series Designator

    uns

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...