AM12HKMG3-10-28VDC5

Circuit Breakers

CIRCUIT BREAKER

AM12HKMG3-10-28VDC5

5925-00-822-0261

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Boss Height

    0.140 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3000.0 dc single location

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Switch Terminal Type

    tab w/screw

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Terminal Type And Quantity

    2 threaded stud

  • Body Length

    2.500 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Mounting Surface To Terminal End Distance

    2.471 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Inclosure Protection Type For Which Designed

    moisture resistant and fungus resistant and explosion resistant

  • Pole Quantity

    1

  • Switch Contact Arrangement

    single pole, double throw

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Ultimate Trip Time Per Pole In Seconds

    0.700 minimum single location and 2.800 maximum single location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc single location

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Actuator Function

    trip-reset

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Body Width

    0.750 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.170 minimum at 200 pct single location and 0.500 maximum at 200 pct single location

  • Reset Method

    manual

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...