LS7501B2
Circuit Breakers
CIRCUIT BREAKER
LS7501B2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
1.859 inches maximum
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Inclosure Protection Type For Which Designed
vibrationproof
-
Body Length
1.122 inches minimum and 1.152 inches maximum
-
Unpackaged Unit Weight
0.100 pounds
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Manual Actuator Type And Quantity
1 push-pull
-
Pole Quantity
1
-
Internal Trip Release Configuration
series trip single location
-
Center To Center Distance Between Terminals Parallel To Length
0.655 inches minimum and 0.685 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 28.0 dc single location
-
Body Width
0.673 inches minimum and 0.703 inches maximum
-
Special Features
includes protection barriers at terminals
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Main Contact Tripping Mechanism Type
trip free
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac single location and 2.0 amperes dc single location
-
Frequency In Hertz
400.0 single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location and 6000.0 dc single location
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Terminal Type And Quantity
2 tab w/screw
-
Bushing Length
0.250 inches maximum
-
Trip Release Characteristic
instantaneous single location
-
Nominal Thread Size
0.469 inches
-
Thread Series Designator
uns
-
Case Material
plastic