77-998B

Circuit Breakers

CIRCUIT BREAKER

77-998B

5925-00-823-2615

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Case Material

    metal

  • Pole Quantity

    1

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.170 minimum at 200 pct single location and 0.620 maximum at 200 pct single location

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Inclosure Protection Type For Which Designed

    moisture resistant and hermetically sealed

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc single location

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Terminal Type And Quantity

    2 wire hook

  • Ultimate Trip Time Per Pole In Seconds

    0.800 minimum single location and 5.000 maximum single location

  • Trip Release Method

    magnetic single location

  • Body Length

    1.500 inches nominal

  • Body Width

    0.640 inches maximum

  • Thread Series Designator

    unef

  • Mounting Surface To Terminal End Distance

    1.605 inches maximum

  • Body Style

    single pole type

  • Test Data Document

    80063-sm-d-414386 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Bushing Length

    0.375 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc single location

  • Trip Release Characteristic

    time delay single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...