7644941P001

Filters and Networks

FILTER,BAND PASS

7644941P001

5915-00-823-9955

5915 - Filters and Networks

Lockheed Martin Corporation

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Specified Frequencies Of Discrimination Per Function

    25.70 kilohertz 1st band pass and 12.50 kilohertz 1st band pass and 24.30 kilohertz 1st band pass and 37.50 kilohertz 1st band pass

  • Inclosure Type

    encased

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.000 inches nominal

  • Nominal Thread Size

    0.190 inches

  • Body Height

    3.125 inches nominal

  • Reference Frequency Per Function

    25.0 single radio interference pulses per second

  • Output Impedance Per Function W/Source Across Input

    30.0 kilohms 1st band pass

  • Output Impedance Per Function W/Source Across Input

    30.0 kilohms 2nd band pass

  • Frequency Band Width Per Function

    25.15 kilohertz 2nd band pass and 26.85 kilohertz 2nd band pass

  • Body Material

    metal

  • Reference Frequency Per Function

    26.0 single radio interference two phase to two phase

  • Style Designator

    rectangular terminal/terminals on one surface

  • Input Impedance Per Function W/Load

    600.0 ohms 1st band pass

  • Overall Height

    3.500 inches nominal

  • Body Length

    4.624 inches nominal

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 maximum 1st band pass and 3.0 maximum 1st band pass and 40.0 minimum 1st band pass and 40.0 minimum 1st band pass

  • Input Impedance Per Function W/Load

    600.0 ohms 2nd band pass

  • Body Width

    2.062 inches nominal

  • Mounting Facility Screw Thread Series Designator

    unf

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 1st band pass

  • Operating Temp Range

    -15.0/+45.0 deg celsius

  • Functional Terminal Type And Quantity

    3 turret input 1st function

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.438 inches nominal

  • Frequency Band Width Per Function

    24.30 kilohertz 1st band pass and 25.70 kilohertz 1st band pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    3.0 maximum 2nd band pass and 3.0 maximum 2nd band pass and 40.0 minimum 2nd band pass and 40.0 minimum 2nd band pass

  • Mounting Facility Type And Quantity

    4 threaded stud

  • Functional Terminal Type And Quantity

    3 turret output 2nd function

  • Unpackaged Unit Weight

    2.500 pounds

  • Specified Frequencies Of Discrimination Per Function

    26.85 kilohertz 2nd band pass and 25.15 kilohertz 2nd band pass and 13.50 kilohertz 2nd band pass and 38.50 kilohertz 2nd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 2nd band pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...