8939528-1

Circuit Breakers

CIRCUIT BREAKER

8939528-1

5925-00-824-7189

5925 - Circuit Breakers

Lockheed Martin Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    8c multipole-multiple actuator type

  • Body Length

    2.469 inches minimum and 2.531 inches maximum

  • Body Width

    2.219 inches minimum and 2.281 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.906 inches minimum and 1.969 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.047 inches minimum and 2.078 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.059 inches minimum and 0.766 inches maximum

  • Boss Height

    0.094 inches minimum and 0.156 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Release Characteristic

    time delay all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 threaded stud

  • Center To Center Distance Between Terminals Parallel To Width

    0.734 inches minimum and 0.766 inches maximum

  • Mounting Surface To Terminal End Distance

    2.328 inches minimum and 2.391 inches maximum

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct and 0.700 maximum at 200 pct all locations

  • Frequency In Hertz

    400.0 all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...