XAM333MG3-15-115VAC60-5

Circuit Breakers

CIRCUIT BREAKER

XAM333MG3-15-115VAC60-5

5925-00-825-3241

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.090 minimum at 300 pct all locations and 1.000 minimum at 150 pct all locations and 6.000 maximum at 150 pct all locations and 0.800 maximum at 200 pct all locations and 0.250 minimum at 200 pct all locations and 0.300 maximum at 300 pct all locations

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Surface To Terminal End Distance

    2.611 inches nominal

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Unpackaged Unit Weight

    14.000 ounces

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Nominal Thread Size

    0.138 inches

  • Frequency In Hertz

    60.0 all locations

  • Body Width

    2.250 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Body Length

    2.500 inches nominal

  • Boss Height

    0.140 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...