65A7A8-1
Coils and Transformers
TRANSFORMER,AUDIO FREQUENCY
65A7A8-1
TRANSFORMER,AUDIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Impedance Rating In Ohms
10000.0 minimum single component single primary and 12000.0 maximum single component single primary
-
Body Outside Diameter
0.350 inches maximum
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Maximum Transformer Power Rating
100.0 milliwatts single component
-
Terminal Type And Quantity
6 wire lead
-
Maximum Operating Temp
105.0 deg celsius
-
Winding Tap Location (Non-Core)
center tap single component single secondary
-
Frequency Rating
400.0 hertz minimum single component and 100.0 kilohertz maximum single component
-
Impedance Rating In Ohms
500.0 minimum single component single secondary and 600.0 maximum single component single secondary
-
Winding Operating Current
1.0 milliamperes maximum of standard range b and better drop siding single component single primary
-
Winding Tap Location (Non-Core)
center tap single component single primary
-
Inclosure Type
hermetically sealed
-
Mounting Method
terminal single group
-
Test Data Document
10001-65a7a8 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Reliability Indicator
not established
-
Body Length
0.406 inches maximum
-
Frequency Response Tolerance In Decibels (Non-Core)
-3.0/+3.0 single component