26072

Circuit Breakers

CIRCUIT BREAKER

26072

5925-00-826-6901

5925 - Circuit Breakers

Bangor Mfg Co Div Of Applied Power

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    5.240 inches minimum and 5.260 inches maximum

  • Body Width

    2.990 inches minimum and 3.010 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Length

    4.349 inches minimum and 4.369 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    series trip third location

  • Frequency In Hertz

    60.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip second location

  • Body Style

    multipole-single actuator type

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    70000.000 nominal at 200 pct all locations and 20000.000 nominal at 300 pct all locations

  • Actuator Position Designation

    at pole two

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    magnetic all locations

  • Terminal Type And Quantity

    6 threaded stud and 2 wire lead

  • Arc Quenching Method

    air

  • Thread Quantity Per Inch

    32

  • Ultimate Trip Time Per Pole In Seconds

    10000.000 nominal all locations

  • Body Height

    2.677 inches minimum and 2.697 inches maximum

  • Boss Height

    0.209 inches minimum and 0.229 inches maximum

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Thread Series Designator

    unf

  • Reset Method

    manual

  • Nominal Thread Size

    0.190 inches

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.302 inches minimum and 2.322 inches maximum

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.974 inches minimum and 0.994 inches maximum

  • Case Material

    plastic

  • Internal Trip Release Configuration

    relay trip first location

  • Center To Center Distance Between Terminals Parallel To Width

    0.974 inches minimum and 0.994 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.