Technical Characteristics

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc all locations

  • Nominal Thread Size

    0.375 inches

  • Body Width

    1.271 inches minimum and 1.291 inches maximum

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Terminal Type And Quantity

    4 wire hook

  • Body Style

    multipole-single actuator type

  • Body Length

    1.552 inches minimum and 1.572 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.865 inches minimum and 0.885 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct all locations and 5.000 maximum at 200 pct all locations

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes dc second location

  • Fragility Factor

    moderately rugged

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Bushing Length

    0.365 inches minimum and 0.385 inches maximum

  • Thread Series Designator

    unef

  • Center To Center Distance Between Terminals Parallel To Width

    0.615 inches minimum and 0.635 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    500.0 milliamperes dc first location

  • Inclosure Protection Type For Which Designed

    explosion resistant and fungus resistant and hermetically sealed

  • Mounting Surface To Terminal End Distance

    1.690 inches minimum and 1.710 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...