4524-3208-3

Circuit Breakers

CIRCUIT BREAKER

4524-3208-3

5925-00-826-8887

5925 - Circuit Breakers

Trane U.s. Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac all locations

  • Body Width

    1.500 inches nominal

  • External Actuator Linkage Arrangement

    one and two linked

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Switch Location And Position Designation

    internal at pole two

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Current Rating And Type In Amps

    2.5 ac and 1.0 dc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Frequency In Hertz

    60.0 all locations

  • Mounting Surface To Terminal End Distance

    2.471 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Unpackaged Unit Weight

    8.500 ounces

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Body Length

    2.500 inches nominal

  • Boss Height

    0.140 inches nominal

  • Manual Actuator Type And Quantity

    2 toggle

  • Maximum Continuous Load Current Rating Per Pole

    18.0 amperes ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.800 minimum at 200 pct all locations and 10.000 maximum at 200 pct all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Terminal Type And Quantity

    4 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...