G330007-2

Circuit Breakers

CIRCUIT BREAKER

G330007-2

5925-00-828-5293

5925 - Circuit Breakers

Itt Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    5.245 inches minimum and 5.255 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    2.927 inches minimum and 2.937 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.185 inches minimum and 0.195 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.354 inches minimum and 4.364 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.995 inches minimum and 1.005 inches maximum

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Storage Type

    general purpose warehouse

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac

  • Trip Release Characteristic

    time delay

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct and 20.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    explosion proof and vibrationproof and shock resistant and fungus resistant and moisture resistant

  • Unpackaged Unit Weight

    1.800 pounds

  • Precious Material

    silver

  • Body Width

    2.995 inches minimum and 3.005 inches maximum

  • Body Height

    2.682 inches minimum and 2.692 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    1.995 inches minimum and 2.005 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.577 inches minimum and 0.587 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic-hydraulic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at pole two

  • Internal Trip Release Configuration

    series trip

  • Frequency In Hertz

    60.0

  • Precious Material And Location

    contact surfaces silver

  • Terminal Type And Quantity

    6 compression

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...