Technical Characteristics

  • Contact Material

    silver

  • Main Contact Load Current Rating At Maximum Rated Voltage

    1.0 amperes ac inductive load and 1.0 amperes dc inductive load

  • Coil Quantity

    1

  • Unthreaded Mounting Hole Diameter

    0.088 inches minimum single mounting facility and 0.098 inches maximum single mounting facility

  • Storage Type

    general purpose warehouse

  • Fragility Factor

    moderately rugged

  • Precious Material And Location

    contacts silver and contact surfaces gold

  • Mounting Facility Type And Quantity

    2 unthreaded hole single mounting facility

  • Overall Width

    0.400 inches maximum

  • Precious Material

    silver and gold

  • Nonpile-Up Main Contact Arrangement

    2 pole, double throw, one position momentary

  • Operating Voltage Rating And Type At Specified Temp

    26.5 volts dc 25 deg celsius single winding

  • Time Delay

    0.006 seconds maximum fixed operate and release time

  • Winding Dc Resistance Rating

    4.5 kilohms minimum single winding and 5.5 kilohms maximum single winding

  • Environmental Protection

    hermetic

  • Nominal Operating Current Rating And Type

    12.0 milliamperes dc single winding

  • Arc Quenching Method

    air

  • Overall Height

    1.040 inches maximum

  • Winding Quantity

    1

  • Cubic Measure

    0.561 cubic inches

  • Features Provided

    polarized

  • Main Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Contact Surface Treatment

    gold

  • Terminal Type And Quantity

    8 pin all functions

  • Purpose For Which Designed

    general

  • Main Contact Load Current Rating At Maximum Rated Voltage

    2.0 amperes ac resistive load and 2.0 amperes dc resistive load

  • Overall Length

    1.350 inches maximum

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    1.090 inches minimum single mounting facility and 1.110 inches maximum single mounting facility

  • Duty Type

    continuous

  • Mounting Facility Pattern

    in-line single mounting facility

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...