E3100

Circuit Breakers

CIRCUIT BREAKER

E3100

5925-00-828-8356

5925 - Circuit Breakers

Westinghouse Electric Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct all locations and 60.000 maximum at 200 pct all locations

  • Thread Series Designator

    unc

  • Body Width

    4.125 inches nominal

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    7500.0 ac all locations and 7500.0 dc all locations

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Body Style

    multipole-single actuator type

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Actuator Position Designation

    at pole two

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Thread Quantity Per Inch

    32

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac all locations and 100.0 amperes dc all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.500 inches nominal

  • Trip Release Method

    thermal all locations

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 250.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Length

    5.062 inches nominal

  • Body Height

    3.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Body Length

    6.000 inches nominal

  • Terminal Type And Quantity

    6 screw

  • Boss Height

    0.125 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    60.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Manual Actuator Type And Quantity

    1 toggle

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...