484653

Circuit Breakers

CIRCUIT BREAKER

484653

5925-00-828-9231

5925 - Circuit Breakers

Lockheed Martin Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    trip-reset

  • Inclosure Protection Type For Which Designed

    dustproof

  • Body Width

    4.120 inches minimum and 4.130 inches maximum

  • Body Height

    3.807 inches minimum and 3.817 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    7.245 inches minimum and 7.255 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.276 inches minimum and 0.286 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.369 inches minimum and 1.379 inches maximum

  • Pole Quantity

    3

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac and 30.0 amperes dc all locations

  • Body Style

    11b multipole-single actuator type

  • Body Length

    9.370 inches minimum and 9.380 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    1.369 inches minimum and 1.379 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.495 inches minimum and 4.505 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.120 inches minimum and 0.130 inches maximum

  • Arc Quenching Method

    deion

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac and 250.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac and 10000.0 dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Trip Release Characteristic

    instantaneous all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole two

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Frequency In Hertz

    60.0

  • Terminal Type And Quantity

    6 compression

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...