711575-7REVB
Circuit Breakers
CIRCUIT BREAKER
711575-7REVB
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
2c multipole-multiple actuator type
-
Body Length
2.485 inches minimum and
-
Body Width
2.235 inches minimum and
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
1.205 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and
-
Center To Center Distance Between Terminals Parallel To Width
0.765 inches maximum
-
Unthreaded Mounting Hole Diameter
0.180 inches minimum and
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.735 inches minimum and
-
Iii Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
1.985 inches minimum and
-
Pole Quantity
3
-
Mounting Facility Type And Quantity
6 threaded hole and
-
Iii Special Handling Feature
magnetic
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
1.25 amperes ac and
-
Maximum Continuous Load Current Rating Per Pole
1.25 amperes dc all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac and
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac and
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc all locations
-
Trip Release Characteristic
time delay all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Manual Actuator Type And Quantity
3 toggle
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.900 maximum at 200 pct all locations
-
Frequency In Hertz
400.0 all locations
-
Thread Series Designator
unc
-
Body Length
2.515 inches maximum
-
Body Width
2.265 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.175 inches minimum and
-
Unthreaded Mounting Hole Diameter
0.188 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.797 inches minimum and
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.827 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.765 inches maximum
-
Mounting Surface To Terminal End Distance
2.015 inches maximum
-
Mounting Facility Type And Quantity
6 unthreaded hole
-
Iii Storage Type
general purpose warehouse
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Method
magnetic all locations
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Position Designation
at each pole
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 minimum at 200 pct and
-
Inclosure Protection Type For Which Designed
shockproof
-
Iii Unpackaged Unit Weight
0.810 pounds
-
Terminal Type And Quantity
6 tab w/screw