Technical Characteristics

  • Body Length

    2.485 inches minimum and 2.515 inches maximum

  • Body Width

    2.235 inches minimum and 2.265 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.180 inches minimum and 0.188 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Pole Quantity

    3

  • Maximum Continuous Load Current Rating Per Pole

    1.5 amperes ac and 1.5 amperes dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac and 50.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac and 2000.0 dc all locations

  • Body Style

    2c multipole-multiple actuator type

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 tab w/screw

  • Thread Series Designator

    unc

  • Unpackaged Unit Weight

    0.810 pounds

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Trip Release Method

    magnetic all locations

  • Thread Quantity Per Inch

    32

  • Special Handling Feature

    magnetic

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    6 threaded hole and 6 unthreaded hole

  • Mounting Surface To Terminal End Distance

    1.985 inches minimum and 2.015 inches maximum

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.797 inches minimum and 1.827 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.175 inches minimum and 1.205 inches maximum

  • Frequency In Hertz

    400.0

  • Inclosure Protection Type For Which Designed

    shockproof

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct and 0.900 maximum at 200 pct all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay all locations

  • Circuit Protection Type

    overcurrent all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...