9078
Resistors
RESISTOR,VARIABLE,NONWIRE WOUND,PRECISION
9078
RESISTOR,VARIABLE,NONWIRE WOUND,PRECISION
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Resistance Tolerance Per Section In Percent
-20.0/+20.0 2nd section
-
Fixed Tap Quantity Per Section
1 4th section
-
Effective Electrical Rotation In Deg Angular Rotation
350.0 nominal
-
Function Conformity Tolerance Per Section
-0.02/+0.02 all sections
-
Pilot Diameter Runout
0.001 inches
-
Shaft Style
round
-
Function Conformity Per Section
all sections absolute conformity
-
Electrical Resistance Per Section
570.0 ohms c and better industrial clears
-
Body Style
cylindrical servo mounted
-
Electrical Resistance Per Section
50.0 percent, rated amperes c and better v.g. stepping
-
Overall Diameter
3.364 inches maximum
-
Shaft Diameter
0.250 inches maximum
-
Rotary Actuator Travel In Angular Deg
360.0 nominal
-
Actuator Type
single shaft
-
Undercut Width
0.0600 inches minimum
-
Reliability Indicator
not established
-
Mounting Lip Diameter
3.0050 inches maximum
-
Actuator Travel Control Feature
continuous motion
-
Lateral Runout
0.003 inches
-
Body Length
5.000 inches maximum
-
Resistance Tolerance Per Section In Percent
-10.0/+10.0 4th section
-
Electrical Resistance Per Section
20.0 percent, rated amperes c finish
-
Resistance Tolerance Per Section In Percent
+0.0/+20.0 3rd section
-
Mounting Method
clamp ring
-
Resistance Tolerance Per Section In Percent
+0.0/+20.0 7th section
-
Ambient Temp In Deg Celsius Per Section At Full Rated Power
25.0 all sections
-
Mounting Lip Depth
0.0980 inches maximum
-
Pilot Length
0.0550 inches nominal
-
Test Data Document
19200-10545461 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Undercut Diameter
2.875 inches maximum
-
Electrical Resistance Per Section
10.0 percent, rated amperes c and better finish
-
Electrical Resistance Per Section
5.0 percent, rated amperes c drop siding
-
Fixed Tap Quantity Per Section
2 5th section
-
Electrical Resistance Per Section
5.0 percent, rated amperes c and better select
-
Resistance Tolerance Per Section In Percent
-0.5/+0.5 6th section
-
Shaft Length
0.750 inches nominal
-
Power Dissipation Rating Per Section In Watts
4.0 free air all sections
-
Pilot Diameter
2.8750 inches maximum
-
Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius
-400.0/+400.0 all sections
-
Electrical Resistance Per Section
7.0 percent, rated amperes c flooring
-
Terminal Type And Quantity
27 turret
-
Overall Length
5.780 inches maximum
-
Resistance Tolerance Per Section In Percent
-10.0/+10.0 1st section
-
Function Characteristic Per Section
all sections table
-
Section Quantity
7
-
Fixed Tap Quantity Per Section
3 3rd section
-
Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power
150.0 all sections
-
Terminal Location
radially positioned over less than half the circumference
-
Body Diameter
3.125 inches maximum
-
Maximum Starting Torque
7.00 inch-ounces
-
Shaft Runout
0.001 inches
-
Resistance Tolerance Per Section In Percent
+0.0/+20.0 5th section
-
Features Provided
humidity proof