220917

Circuit Breakers

CIRCUIT BREAKER

220917

5925-00-833-6028

5925 - Circuit Breakers

International Business Machines Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    metal

  • Mounting Surface To Terminal End Distance

    1.420 inches maximum

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    2 screw

  • Maximum Continuous Load Current Rating Per Pole

    4.0 amperes ac single location and 4.0 amperes dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Circuit Protection Type

    overcurrent single location

  • Bushing Length

    0.359 inches nominal

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • ~1

    data on certain environmental and performance

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    explosion resistant and moisture resistant

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Body Width

    0.580 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Body Length

    0.780 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    100.0 ac single location and 100.0 dc single location

  • Thread Series Designator

    un

  • Center To Center Distance Between Terminals Parallel To Length

    0.593 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...