74-100-3

Circuit Breakers

CIRCUIT BREAKER

74-100-3

5925-00-835-2494

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct single location and 70.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    shockproof

  • Unpackaged Unit Weight

    0.230 pounds

  • Reset Method

    manual

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.797 inches minimum and 1.827 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    1.25 amperes ac single location and 1.25 amperes dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac single location and 2000.0 dc

  • Circuit Protection Type

    overcurrent single location

  • Body Style

    4a single pole type

  • Body Length

    2.485 inches minimum and 2.515 inches maximum

  • Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.175 inches minimum and 1.205 inches maximum

  • Mounting Surface To Terminal End Distance

    1.985 inches minimum and 2.015 inches maximum

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 50.0 dc

  • Frequency In Hertz

    60.0 single location

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 tab w/screw

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...