SM3-2-8-23VDC2

Circuit Breakers

CIRCUIT BREAKER

SM3-2-8-23VDC2

5925-00-835-2609

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Inclosure Protection Type For Which Designed

    fungus resistant and explosion resistant and hermetically sealed

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Thread Series Designator

    unef

  • Center To Center Distance Between Terminals Parallel To Length

    0.870 inches minimum and 0.880 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct single location and 0.600 maximum at 200 pct single location

  • Fragility Factor

    moderately rugged

  • Terminal Type And Quantity

    2 wire hook

  • Mounting Surface To Terminal End Distance

    1.524 inches minimum and 1.586 inches maximum

  • Body Width

    0.567 inches minimum and 0.629 inches maximum

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    2.8 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    23.0 dc single location

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Body Length

    1.448 inches minimum and 1.510 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Bushing Length

    0.360 inches minimum and 0.380 inches maximum

  • Pole Quantity

    1

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.