D7271-8-10
Circuit Breakers
CIRCUIT BREAKER
D7271-8-10
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Actuator Function
trip-reset
-
Unpackaged Unit Weight
1.500 ounces
-
Mounting Surface To Terminal End Distance
1.343 inches maximum
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Manual Actuator Type And Quantity
1 push-pull
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches minimum and 0.937 inches maximum
-
Pole Quantity
1
-
Case Material
metal
-
Nominal Thread Size
0.469 inches
-
Thread Series Designator
uns
-
~1
data on certain environmental and performance
-
Test Data Document
81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Internal Trip Release Configuration
series trip single location
-
Inclosure Protection Type For Which Designed
shockproof and moisture resistant and corrosion resistant and dusttight and explosion proof and sand resistant and vibration resistant
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location and 28.0 dc single location
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Main Contact Tripping Mechanism Type
trip free
-
Bushing Length
0.313 inches minimum and 0.375 inches maximum
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac single location and 10.0 amperes dc single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct single location and 70.000 maximum at 200 pct single location
-
Terminal Type And Quantity
2 tab w/screw
-
Body Width
0.750 inches maximum
-
Specification/Standard Data
96906-ms24510 government standard
-
Body Length
1.375 inches maximum
-
Fragility Factor
moderately rugged
-
Reset Method
manual
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
43500.0 ac all locations and 3500.0 dc all locations
-
Actuator Position Designation
at pole one
-
Storage Type