260-4066-330

Circuit Breakers

CIRCUIT BREAKER

260-4066-330

5925-00-836-6205

5925 - Circuit Breakers

Rockwell Collins Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Method

    magnetic-hydraulic single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc single location

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and explosion resistant

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.170 minimum at 200 pct single location and 0.500 maximum at 200 pct single location

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Body Width

    0.750 inches nominal

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Actuator Function

    trip-reset

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Ultimate Trip Time Per Pole In Seconds

    0.700 minimum single location and 2.800 maximum single location

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Mounting Surface To Terminal End Distance

    2.471 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Length

    2.500 inches nominal

  • Boss Height

    0.140 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Body Style

    single pole type

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Switch Terminal Type

    tab w/screw

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Terminal Type And Quantity

    2 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...