1500-052-105

Circuit Breakers

CIRCUIT BREAKER

1500-052-105

5925-00-837-1896

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.380 minimum at 200 pct single location and 2.500 maximum at 200 pct single location

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Inclosure Protection Type For Which Designed

    vibrationproof and shockproof

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Body Length

    1.127 inches minimum and 1.147 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    1.5 amperes ac single location and 1.5 amperes dc single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Unpackaged Unit Weight

    45.0 grams

  • Main Contact Tripping Mechanism Type

    trip free

  • Precious Material And Location

    contact surfaces silver

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Mounting Surface To Terminal End Distance

    1.843 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.690 inches minimum and 0.710 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 6000.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Width

    0.750 inches maximum

  • Trip Release Characteristic

    instantaneous single location and time delay single location

  • Nominal Thread Size

    0.469 inches

  • Bushing Length

    0.205 inches minimum and 0.295 inches maximum

  • Thread Series Designator

    uns

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...