Technical Characteristics
-
Boss Height
0.109 inches minimum and 0.141 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.876 inches minimum and 2.000 inches maximum
-
Case Material
plastic
-
Terminal Type And Quantity
2 threaded stud
-
Mounting Surface To Terminal End Distance
2.690 inches maximum
-
Fragility Factor
moderately rugged
-
Thread Series Designator
unc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac single location
-
Reset Method
manual
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.046 inches minimum and 2.078 inches maximum
-
Actuator Position Designation
at pole one
-
Precious Material
silver
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Body Length
2.484 inches minimum and 2.516 inches maximum
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 minimum at 200 pct single location and 60.000 maximum at 200 pct single location
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac single location
-
Precious Material And Location
terminals silver
-
Pole Quantity
1
-
Inclosure Protection Type For Which Designed
moisture resistant and fungus resistant and explosion resistant
-
Maximum Continuous Load Current Rating Per Pole
400.0 milliamperes ac single location
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Body Width
0.734 inches minimum and 0.766 inches maximum
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Trip Release Method
magnetic-hydraulic single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location