290201
Coils and Transformers
TRANSFORMER,POWER
290201
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Body Height
4.250 inches maximum
-
Nominal Thread Size
0.164 inches single group
-
Winding Tap Location (Non-Core)
err-070
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.297 inches nominal single mounting facility single center group
-
Mounting Method
threaded stud single group
-
Thread Quantity Per Inch
32 single group
-
Body Width
2.620 inches maximum
-
Frequency Rating
60.0 hertz minimum single component and 400.0 hertz maximum single component
-
Winding Operating Voltage
24.80 ac volts nominal single component 2nd secondary
-
Overall Height
4.650 inches maximum
-
Winding Operating Current
110.0 milliamperes ac maximum single component 2nd secondary
-
Winding Operating Voltage
120.00 ac volts nominal single component single primary
-
Maximum Operating Temp
71.0 deg celsius
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.859 inches nominal single mounting facility single center group
-
Reliability Indicator
not established
-
Winding Operating Voltage
41.00 ac volts nominal single component 3rd secondary and 45.40 ac volts nominal single component 3rd secondary
-
Body Length
3.060 inches maximum
-
Thread Class (Non-Core)
err-070
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Shielding Method
internal shield grounded to core single component
-
Inclosure Type
hermetically sealed
-
Thread Series Designator
unc single group
-
Terminal Type And Quantity
10 solder stud
-
Winding Operating Voltage
22.20 ac volts nominal single component 1st secondary
-
Winding Operating Current
1.14 amperes ac maximum single component 3rd secondary
-
Winding Function And Quantity
1 primary single component and 3 secondary single component
-
Winding Operating Current
1.37 amperes ac maximum single component 1st secondary