TEC36050

Circuit Breakers

CIRCUIT BREAKER

TEC36050

5925-00-840-2585

5925 - Circuit Breakers

General Electric Co

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Height

    3.375 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    5.875 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations

  • Unthreaded Mounting Hole Diameter

    0.203 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    6 compression

  • Frequency In Hertz

    60.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Boss Height

    0.250 inches nominal

  • Body Style

    multipole-single actuator type

  • Actuator Position Designation

    at pole two

  • Trip Release Method

    magnetic all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    95.000 minimum at 200 pct all locations and 250.000 maximum at 200 pct all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.875 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Body Length

    6.312 inches nominal

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Body Width

    4.125 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...